Introduction
Prerequisites
Requirements
Components Used
Launching Download Manager
Locating Download Manager
Setting the Preferences and and Superuser password
Loading Firmware on the Chassis and Modules
Connect to the chassis
Select the modules and start the download
Loading RPM files on the modules
Getting ready to load the RPM files
The purpose of this document is to provide a user step-by-step
instructions on how to upgrade
firmware and RPM files on a SmartBits 600/6000 chassis.
Note: RPM files are only required if TeraRouting Tester (TRT)
support is needed.
The following are required prior to installing firmware on the chassis
The following components were used in this sample upgrade
NOTE: Before starting, make sure the chassis is set to 10Mbps half-duplex (see below)

Step #1: Open Windows explorer, and go to the directory where firmware was installed
(C:\Program Files\SmartBits\Firmware\SMB6X) is the default
Step #2: Find “fdlmgr.exe and double click it…window below opens up

Step #3: Click on the small chassis icon
In the window that opens, type in the chassis IP address, and make sure
you are able to PING it
Click OK

Step #4: Go to Superuser access mode
Click on Actions, Preferences
Check "Enter SMB Superuser mode"
Password is SMB-6000 (case sensitive)

Step #5: Click the Connect icon or hit F8

Step #6: Click on green “LED” next to the card (or
controller) you want to upgrade (to reserve it)… LED turns blue
Click on the Download button to begin downloading the Firmware
Red flames will appear on the screen while the flash is being burned; Several messages
appears as it progresses.
You will be advised at the end if the upgrade was successful. A reboot will be
required.
NOTE: Do not interrupt after the upgrade has started.

NOTE: Steps #6-7 are optional. Proceed only if RPM files are needed (used for TRT, etc)
Step #6: Select the "Software (RPM)" tab and click the Green LED next to the module requiring the RPM file

Step #7: Click on Files and select "Add to All Reserved
Modules"
By default, RPM files are located in the default directory where TRT is
installed
C:\Program Files\SmartBits\TRT Interactive\RPM
Note: FOR TRT 6.00 and
above:
RPM file
trt-6.00.022.rpm is for the newer TeraMetrics cards (e.g. LAN-33xx,
LAN-3721-A)
RPM
file trt-16.00.022.rpm is for the older TeraMetrics cards (e.g. LAN-3311A,
LAN-3301A)
Click on the Download button and confirm by clicking OK. A notification will be provided after the file has been installed
NOTE: Do not interrupt the service after the installation has started.

| NOTE: For informational use only |